Two-stage Reciprocating Compressor
Air-cooled, Oil-free
3 to 30 Horsepower (13 sizes available)
VRU flows from 15 to 5 MSCFD @atmos
Flash gas booster flows to 400 Mscfd
Inlet pressure: 0 to 80 Psig
Discharge pressures: up to 260 Psig
Air-cooled, Oil-free
3 to 30 Horsepower (13 sizes available)
VRU flows from 15 to 5 MSCFD @atmos
Flash gas booster flows to 400 Mscfd
Inlet pressure: 0 to 80 Psig
Discharge pressures: up to 260 Psig
The TESCORP "BVR-MODULAR 2" Series is a completely self-contained compression system for applications for stock tank vapor recovery, flare gas recovery, or small flow, medium pressure process gas applications. Constructed as a compact and fully-contained system, it is constructed with a Blackmer air-cooled, two-stage, pressure-lubricated,reciprocating gas compressor and TESCORP vapor recovery unit technology and components. The BVR-MODULAR 2 Vapor Recovery Unit is designed and constructed for simplicity of installation and ease of operation for the critical demands of the harsh oilfield environment.
*Price available upon request
The unit offers the following design and optional features:
Two-stage reciprocating compressor with:
Two-stage, single-acting, air-cooled pressure lubricated power-frame compressor
Single distance piece and seal assembly
Corrosive gas trim
Premium efficiency electric motor drive with:TEFC enclosure, NEMA "B" torque, 1.15 service factor
Suction scrubber constructed per the following:Designed, constructed, stamped and National Board Certified per ASME Section VIII
1/8" corrosion allowance
Condensate level controls, gauges, pump rated for flow and pressure
Piping materials, welding procedures, design and construction are per the following:All gas transmission piping 2” and smaller shall be
either NPT or tubing
ANSI B31.3 latest edition
Premium efficiency electric motor drive with:
Suction scrubber constructed per the following:
Piping materials, welding procedures, design and construction are per the following:
Vapor Recovery Control Panel is designed per NEC Class I, Division II, Class B, C & D with:
TESCORP vapor recovery logic, controls and indicators
Load/unload flow control and control logic
BVR-MODULAR 2 Unit Construction:All electrical components and wiring per NEC Class I, Division II, Class B, C & D
All rotating equipment is fully protected with non-sparking guards
All units receive a complete mechanical/control run test with documentation
Options:Controls and panels per customer preference
Motor starters and/or VFD drives
2 or 3 piece distance piece and seal assemblies
available
Sour gas trim for compressor available
BVR-MODULAR 2 Unit Construction:
Options: